| Specifications |
| Measurement Subject |
Panel(with mask), q value(thickness of glass+q=35mm MAX) Each * height of mask and mask assembly treatment jig |
| Measuring item |
CRT fluorescent surface and shadow mask surface distance"q" *height of mask and mask assembly jig (By PC control) |
| Measurement method |
Optical reflection method |
| Resolving power |
4 µm |
| q measuring accuracy |
±0.020 mm(repetition) * Gauge measuring accuracy ±0.010mm(repetition) |
| Measuring time |
3 seconds(1 Point and nine point measurement mode) |
| Input-output control |
RS-232C |
| Use environment |
Temperature 5ºC-40ºC Humidity MAX 85% |
| Power supply voltage |
AC100V, 50/60Hz |