| Specifications |
| Measurement Subject |
Shutter unit of digital camera and camera phone |
| Measuring item |
TH(Beginning shutting-Time to 50%LEVEL) TE(EXT.TRIG signal input-Time to 50%LEVEL) T2(Shutting time)

|
| Display |
Each measuring item value(1ch, effective 4fig. indications) Judgment result(each RED) |
| Measuring range |
Effective 4fig. indications, 1ch(7 segment) LED |
| Measuring |
32.768ms after "EXT TRIG" |
| Measurement method |
The shutter caliber at the time of an EXT.TRIG signal input is made into 100%. The timing of DC LEVEL is detected optically. |
| Wave pattern resolution |
10µs |
| Measuring wavelength |
Halogen lamp |
| Mesuring accuracy |
±20µs |
| Judgment function |
Each measuring item Has uneven judgment in TE and T2 |
| Input-output |
RS-232C Transmits measurement data to PC WAVE OUT Motion wave pattern output EXT TRG Shutter trigger signal input |
| Power supply |
AC100V(±10) 50/60HZ |
| Power consumption |
30VA |
| Dimensions&Weight |
280(W)x315(H)x200(D)mm About 5.5kg |
| External control |
EXT START START SW input |
| Light Source |
Halogen lamp Parallel light source Φ30 |