Corresponds to one digital eyes lev camera. 9 points measurement |
| * |
Measurement is possible by finished camera |
| * |
High-speed 1 / 8000-sec correspondence |
| * |
Automatic sensitivity adjustment |
| * |
Seven times measurements in a second |
| * |
Start time lag of left, center and right |
|
|
| Specifications |
| Measurement Subject |
Focal-plane shutter unit, shutter unit, finished camera |
| Measuring item |
|
| Function table
|
Left,Center,Right x Top,Center,Bottom=9point
|
| |
EXP |
X |
RUN |
| 1C |
1C Front curtain drive time |
1C Front curtain drive time |
1C Front curtain drive time |
| 2C |
2C Rear curtain drive time |
2C Rear curtain drive time |
2C Rear curtain drive time |
| A |
TOP Forward end exposure time |
+ X delay time |
1st HALF First half of front curtain |
| B |
CENT Center exposure time |
X + X margin time |
2nd HALF First half of rear curtain |
| C |
BOTT Rear end exposure time |
FULL Fully open time |
CENT Center exposure time |
|
BOUND detection(LED lamp) HASTY detection(LED lamp)
|

|
|
| Display |
5ch(7 segment) |
| Measuring range |
0.001(msec)-16(sec) |
| Measuring |
0.001ms-16.0s |
| Measurement method |
Reflection method Φ0.1mm laser spot light is irradiated to the front of a CCD element (filter section). Catoptric light is detected when a shutter of source container opens. Push the shutter release before measurement , it is caribrated automatically |
| Wave pattern resolution |
5µs |
| Measuring wavelength |
Laser spot light λ=780nm Output/mw,class2x9Beams |
| Mesuring accuracy |
MAX ±5µs |
| Judgment function |
Unavailable |
| Input-output |
RS-232C |
| Power supply |
AC100-120,200-240V 50/60HZ |
| Power consumption |
16VA |
| Dimensions&Weight |
234(W)x380(D)x483(H) 11kg |
| External control |
RS-232C |
| Light Source |
Laser spot light λ=780nm Output/mw,class2x9Beams |
|
|
|
|
 |
|
|